Designed to meet the requirements of MIL-PRF-39016/14
|
| |
|
Contact Arrangement:
4PDT (4 Form C)
|
|
Weight:
0.3 oz max.
|
|
|
| |
Contact Rating:
For case grounded loads and other ratings, consult the factory.
|
|
Resistive :
Case Ungrounded
|
| |
|
2 Amp @ 28 VDC
|
| |
|
0.5 Amp @ 115V 60 + 400 Hz
|
|
Inductive:
0.5 Amp @ 28 VDC
|
|
Lamp:
0.1 Amp @ 28 VDC
|
|
Low Level:
10-50µA @ 10-50 mv DC or peak AC
Relay contacts which have switched high level currents are no longer suitable for switching low level loads.
|
|
Life:
100,000 operations minimum @ 1 amp load, 125°C
|
|
Pull In Power:
250 mw approx.
|
|
Operate/Release Time:
4 ms max, excluding bounce time at nominal coil voltage
|
|
Contact Bounce Time:
2 ms max @ 1 Amp
|
|
Contact Resistance:
|
|
Before Life:
0.050 Ohms max @ 1 Amp and 6 VDC
|
|
After Life:
0.150 Ohms max @ 1 Amp and 6 VDC
|
|
|
| |
|
Temperature Range:
-65°C to +125°C
|
Vibration:
0.4" DA 10 - 38 Hz, 30 G's 38 - 2,000 Hz
For applications requiring other vibration levels, consult the factory.
|
Shock (Operating):
75 G's 11 ms
For applications requiring other shock levels, consult the factory.
|
| |
Electrical Characteristics
|
|
|
| |
|
Duty Cycle:
Continuous
|
|
Insulation Resistance:
|
|
@ 500V 25°C:
10,000 megohms
|
|
@ 500V 125°C:
1,000 megohms
|
|
Dielectric Strength:
|
|
Sea Level:
|
| |
|
Contact to Case
750 VRMS
|
| |
|
Contact to Coil
750 VRMS
|
| |
|
Coil to Case
500 VRMS
|
| |
|
Across Open Contacts
500 VRMS
|
|
70,000 Feet:
|
| |
|
All points
350 VRMS
|